NSF STANDARD 53 TEST PROTOCOL

PERFORMED BY INDEPENDENT LABORATORY

The table below shows the test results for our KDF/GAC cartridge in its ability to remove high levels of contaminants (chlorine, pesticides and heavy metals) added to municipal water.  After 20,000 gallons, our cartridge was still removing 99+% of the chlorine. Other non-standard tests show results after just one pass through the filter.  Our test was more thorough.  To pass the NSF-53 protocol, the effluent must be under the EPA Maximum Contaminant Level (mg/l) throughout the test.

Chemical Influent Effluent Efficiency EPA Maximum Contaminant Level - mg/l
THM (chloroform) 0.57 0.029 95% 0.1
Lead 0.19 0.006 97% 0.025
Barium 10.4 0.56 95% 1.0
Arsenic(1) 0.37 0.007 98% 0.05
Cadmium 0.03 0.004 87% 0.01
Chromium VI 0.15 0.011 93% 0.05
Chromium III 0.163 0.003 98% 0.05
Selenium 0.1 0.006 94% 0.01
Mercury 0.006 0.000* 99+% 0.002
Endrin 0.0008 0.000* 99%+ 0.0002
Lindane 0.011 0.0012 89% 0.004
Methoxychlor 0.32 0.0059 98% 0.1
Toxaphene 0.013 0.000* 99%+ 0.005
2,4-D 0.3 0.02 93% 0.1
Silvex (2,4,5-TP) 0.029 0.004 86% 0.01

* - Below detectable limit.

(1) - Inorganic Arsenic

A separate test was run to determine chlorine removal capacity. The challenge solution contained 3 mg/l chlorine (most cities use less than 1 mg/l). 2 mg/l lead was also added. At 20,000 gallons, both were being removed 99.9+%. The test was terminated at 28,400 gallons when the chlorine removal rate hit 90%. The lead removal was still 97.6%.

We offer special nitrate and fluoride filters if removal is needed.

Other KDF/GAC Test Data

NSF-53 KDF-55 Test Results Listed at KDF Fluid Treatment

Chlorine Removal Test 1: KDF 55 Shower Filter

Bacteria Test 1

Bacteria Test 2

Lead Removal Test

Case Studies

Chlorine Removal       

Hydrogen Sulfide Removal

Microorganism Growth Control

Heavy Metal Removal

Iron Removal

Microbrewery Application

Scale Removal

 

nsf-53 test

 

 

logo